Weights calibration Troemner cales and Balances

Industrial Crane Scales and Custom Digital Weighing Systems

5000 lb. FLOOR SCALES

 

 

 

  Sales Calibration Rentals
PRODUCTS

Floor Scales, Balances, Price Computing Scales and Bench Scales are available everyday

Henry Troemner Calibration Test Weights
Alloy 8 Stainless Steel Precision Weights Suggested Application

Troemner OIML Precision Weights conform to the standards of the Organisation Internationale de Metrologie Legale International Recommendation (OIML R 111). They are manufactured from the finest stainless steels available including Troemner Alloy 8 Stainless Steel that has low magnetic permeability, uniform consistency and high resistance to corrosion. Troemner OIML Precision Weights are available in Classes E1, E2, F1 and F2, where Class E1 has the smallest tolerances and Class F2 has the largest tolerances. The letter "E" for Classes E1 and E2 refers to "extra fine" where the letter "F" for Classes F1 and F2 refers to "fine". OIML R 111 weight specifications are designed so the specifications on surface finish, markings, construction, material density and magnetic properties get more restrictive as the weight tolerances get smaller in order to enable the weight to maintain its tolerance over time. The tolerances for the various classes are established in a manner that enables weights of higher classes to calibrate weights of the next lowest class. For example, Class E2 weights can be used to calibrate Class F1 weights. Troemner OIML Precision Weights and Weight Sets are supplied with Troemner's Statement of Accuracy, which details the date of calibration and accuracy class of each weight. If your laboratory requires more stringent documentation, please see the Weight Calibration and Certificate Options below.

**Caution** Class E1 weights have extremely small tolerances and are intended to be used as primary reference standards with direct traceability to national reference standards. They should be used in extremely stable environments and handled with the highest level of care. Otherwise, Class E1 weights will not maintain their measured value within the tolerance class. One may be tempted to purchase the weights with the tightest tolerances in order to reduce measurement uncertainty. However, frequency of use, care, handling, and environmental conditions all play a major role in long term stability of weights and these factors should be considered before purchasing Class E1 weights.

Henry Troemner Calibration Weights Price List (pdf files below)
Troemner Alloy 8 Stainless Steel Precision Weights  
Troemner Alloy 8 Stainless Steel OIML Precision Weights  
   

Suggested Applications
Class E1 weights are intended for use in metrology laboratories as primary reference standards where the stability of the environment and careful handling are assured. Although very stable, one-piece construction Class E1 weights have no method of adjustment and are not suitable for general laboratory use.

Class E2 weights can be also be used as reference standards as well as calibrating Class I balances as specified in OIML R 76. Class E2 weights can also be used to calibrate Class F1 weights.

Class F1 weights can be used to calibrate certain Class I balances and scales as specified in OIML R 76. Class F1 weights can also be used to calibrate Class F2 weights.

Class F2 weights can be used to calibrate weighing instruments for important commercial transactions like gold and precious stones. They can also be used to calibrate Class M2 weights.



Need a certificate with your Troemner weight? Please look over the following information to determine what certificate you need.

Troemner Certificate Matrix -- See which cert you need
NVLAP Weight Calibration Certificate NVLAP Weight Calibration Certificate is a detailed, multi-page weight certificate designed to meet all of your ISO (including ISO/IEC 17025), FDA, GMP, GLP, DOD, ANSI/NCSL Z540-1, and nuclear requirements. The NIST-administered National Voluntary Laboratory Accreditation Program (NVLAP Lab Code 105013-0) approves all procedures for this detailed weight certificate. The measurement process follows the recommendations of NIST Handbook 145.
Traceable Weight Certificate Traceable Weight Certificate - designed for those laboratories and companies that require traceability, but do not need to meet any stringent regulatory requirements. In contrast to NVLAP or UKAS calibration procedures, the Traceable Weight Certificate measurement process is based on a single standard and utilizes one series of comparisons.
Statement of Accuracy New weights and weight sets supplied without weight certificates come with Troemner's Statement of Accuracy which provides the nominal value, type of weight, material / density and weight class. Note: There is no NIST traceability supplied with this statement. The Statement of Accuracy is not suitable for quality or regulatory requirements. Troemner's Statement of Accuracy is only available with the purchase of new weights. Troemner's Brass Weights are not supplied with a Statement of Accuracy.
Comparison pdf

Prices & Specifications subject to change without notice

 

Troemner weights

Agriculture Scales

Balances

Bench Scales

Check weigh Scales

Coin Counting

Counting Scales

Crane Scales

Digital Readouts

Educational Scales

Farm & Livestock Weighing

Fishing Scales

Industrial Floor Scales

Food & Deli Scales

Intrinsically Safe Scales

Inventory Management

Jewelry Scales

Material Handling

Pallet Truck with Scales

Parts Counting Scale

Physicians Scales

Platform Scales

Pocket Balances

Portable Scales

Portion Control

Price Computing

Remote Displays

Scale Parts & Loadcells

Shipping & Mail Scales

Specials

Troemner Cal Weights

Truck Scales

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

© Copyright 2009. All rights reserved